Error 711

Error 711:  When attempting to start the Routing and Remote Access Service, you may receive "The Routing and Remote Access service terminated with service-specific error 711" and Event ID: 7024  in the System Event log of the server shows. This behavior may occur because the Routing and Remote Access Service is unable to start if the Remote Access Connection Manager service, Remote Access Auto Connection Manager, and the Telephony service are disabled.

RESOLUTION: to resolve this behavior, you must use the Services Administrative tool to set the Startup Type of all the Remote Access Connection Manager service, Remote Access Auto Connection Manager, and the Telephony service to Manual.. After you have made these settings, you can restart the Routing and Remote Access Service.

  • 2 Users Found This Useful
Was this answer helpful?

Related Articles

Error 629

Error 629 - The port was disconnected by the remote machine (also re: error 913).Check lists:1)...

Error 736

Error 736 - The remote computer terminated the control protocol.1. This error indicated that the...

Error 678

Error 678: There was not answer.Resolution:1) you are dialing the wrong number.2) make...

Error 734

Error 734 - The PPP link control protocol terminated.Resolutions: 1. this is most like security...

Error 741

Error 741 - The local computer does not support the required encryption type1. Make...